Uninterruptible Power Supply (UPS), Rated Capacity: 1-10kVA
Product Description
The YTR series UPS incorporates advanced digital control technology, three-level topology, and high-frequency power conversion for superior performance. This compact, high-efficiency UPS system is designed with reliability in mind, providing significant energy-saving benefits that help reduce overall operating costs.
Key Features:
• Compact Design, High Performance: Despite its small footprint, the YTR series delivers outstanding performance and reliability, making it ideal for environments where space is limited but power protection is critical.
• Integrated Power Solutions: The UPS combines AC voltage regulation, backup power, and peak surge absorption into one powerful system. It ensures seamless power protection, even in challenging grid environments.
• Pure, Safe, and Stable Power: Designed to deliver clean and uninterrupted power, the YTR series safeguards sensitive equipment, ensuring optimal performance and minimizing the risk of damage from power fluctuation
Rated capacity: 1-10kVA
Power supply system: Single input and single output
Output voltage: 208/220/230/240Vac
Topological structure: Double conversion on-line
Power supply system: Single input and single output
Output voltage: 208/220/230/240Vac
Topological structure: Double conversion on-line
Applications
• Medical Facilities (Clinics, Labs, etc.)
• Data Centers
• Telecommunication / IT Rooms
• Security Systems
• Manufacturing and Industrial Sites
• Educational Institutions
• Healthcare
Index | Model | YTR1101 | YTR1101L | YTR1102 | YTR1102L | YTR1103 | YTR1103L | YTR1106 | YTR1106L | YTR1110 |
input | Battery voltage (Vdc) | 24 | 36 | 48 | 72 | 72 | 96 | 192 (192~240 can be set) | 192 (192~240 can be set) | 192 (192~240 can be set) |
Voltage range (Vac) | 120~295 | 120~295 | 120~295 | 120~295 | 120~295 | 120~295 | 80ÿ275 | 80ÿ275 | 80ÿ275 | |
Frequency range (Hz) | 50/60±10% (adaptive) | 50/60±10% (adaptive) | 50/60±10% (adaptive) | 50/60±10% (adaptive) | 50/60±10% (adaptive) | 50/60±10% (adaptive) | 50/60±10% (adaptive) | 50/60±10% (adaptive) | 50/60±10% (adaptive) | |
characteristics | Phase | Single-phase three-wire | Single-phase three-wire | Single-phase three-wire | Single-phase three-wire | Single-phase three-wire | Single-phase three-wire | Single-phase three-wire | Single-phase three-wire | Single-phase three-wire |
input power factor | >0.99 (full load) | >0.99 (full load) | >0.99 (full load) | >0.99 (full load) | >0.99 (full load) | >0.99 (full load) | >0.99 (full load) | >0.99 (full load) | >0.99 (full load) | |
Input current harmonics | <5% (full load) | <5% (full load) | <5% (full load) | <5% (full load) | <5% (full load) | <5% (full load) | <5% (full load) | <5% (full load) | <5% (full load) | |
Rated power (VA/W) | 1000/900 | 1000/900 | 2000/1800 | 2000/1800 | 3000/2700 | 3000/2700 | 6000/5400 | 6000/5400 | 10000/9000 | |
output power 24 factor | 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) | 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) | 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) | 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) | 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) | 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) | 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) | 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) | 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) | |
Output voltage (Vac) |
208/220/230/ 240±1% |
208/220/230/ 240±1% |
208/220/230/ 240±1% |
208/220/230/ 240±1% |
208/220/230/ 240±1% |
208/220/230/ 240±1% |
208/220/230/ 240±1% |
208/220/230/ 240±1% |
208/220/230/ 240±1% |
|
Output frequency (Hz) | Mains mode: synchronized with the grid; battery mode: 50/60±0.2% | Mains mode: synchronized with the grid; battery mode: 50/60±0.2% | Mains mode: synchronized with the grid; battery mode: 50/60±0.2% | Mains mode: synchronized with the grid; battery mode: 50/60±0.2% | Mains mode: synchronized with the grid; battery mode: 50/60±0.2% | Mains mode: synchronized with the grid; battery mode: 50/60±0.2% | Mains mode: synchronized with the grid; battery mode: 50/60±0.2% | Mains mode: synchronized with the grid; battery mode: 50/60±0.2% | Mains mode: synchronized with the grid; battery mode: 50/60±0.2% | |
Waveform (THD) | <2% (linear load), <3% (non-linear load) | <2% (linear load), <3% (non-linear load) | <2% (linear load), <3% (non-linear load) | <2% (linear load), <3% (non-linear load) | <2% (linear load), <3% (non-linear load) | <2% (linear load), <3% (non-linear load) | <1% (linear load), <3% (non-linear load) | <1% (linear load), <3% (non-linear load) | <1% (linear load), <3% (non-linear load) | |
Switching time (ms) | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | |
overload capacity | 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms | 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms | 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms | 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms | 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms | 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms | Load<115%: long-term; 115%-130% overload: 10min; 131%-150% overload: 30s; over 150% overload: 0.5s | Load<115%: long-term; 115%-130% overload: 10min; 131%-150% overload: 30s; over 150% overload: 0.5s | Load<115%: long-term; 115%-130% overload: 10min; 131%-150% overload: 30s; over 150% overload: 0.5s | |
output method | output socket | output socket | output socket | output socket | Output socket + terminal block | Output socket + terminal block | Terminal block | Terminal block | Terminal block | |
Overall efficiency | Up to 95% | Up to 95% | Up to 95% | Up to 95% | Up to 95% | Up to 95% | Up to 95% | Up to 95% | Up to 95% | |
DC start | have | have | have | have | have | have | have | have | have | |
communication function | RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) | RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) | RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) | RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) | RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) | RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) | RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) | RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) | RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) | |
panel display | led | led | led | led | led | led | blue screen LCD | blue screen LCD | blue screen LCD | |
other features | Audio noise (dB) | <50 | <50 | <50 | <50 | <55 | <55 | <55 | <55 | <55 |
other features | Alarm function | Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit | Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit | Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit | Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit | Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit | Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit | Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit | Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit | Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit |
other features | Protective function | Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection | Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection | Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection | Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection | Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection | Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection | Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection | Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection | Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection |
other features | Working temperature (ÿ) | -5~40 | -5~40 | -5~40 | -5~40 | -5~40 | -5~40 | -5~40 | -5~40 | -5~40 |
other features | environment humidity | 0 ~ 95%, non-condensing | 0 ~ 95%, non-condensing | 0 ~ 95%, non-condensing | 0 ~ 95%, non-condensing | 0 ~ 95%, non-condensing | 0 ~ 95%, non-condensing | 0 ~ 95%, non-condensing | 0 ~ 95%, non-condensing | 0 ~ 95%, non-condensing |
other features | Dimensions (W×D×H) (mm) | 45×360×225 | 45×360×225 | 90×400×330 | 90×400×330 | 90×400×330 | 90×400×330 | 230×502×553 | 190×422×337 | 190×422×337 |
other features | Weight (kg) | 9.2 | 4.5 | 17.7 | 8.5 | 22.9 | 9.2 | 54.5 | 11 | 12.5 |